« The database principal owns a database role and cannot be dropped | Main
December 07, 2012
Error 155 Illegal Null Parameter during Assign Item in Vault Pro 2013
In Vault Pro 2012 we also had the issue with the error 155 during assign item and the solution was mentioned in this article Error 155 When Trying To Assign Item on Vault Pro 2012.
However if you have this error "Error 155 Illegal Null Parameter" in Vault Pro 2013 the solution mentioned here (checkout file, rebuild all in Inventor, check back in) usually doesn´t help.
You will need to reinstall the Vault Server 2013.
Before this you should be sure that you have a valid backup of your Vault.
Steps to reinstall the Vault Server:
1. Go to Control Panel
2. Go to Programs and Features
3. Go to Autodesk Vault Professional 2013 (Server) and choose "Uninstall/Change"
4. On the Setup Pick "Repair or Reinstall"
5. Select Reinstall and start the operation
If this was successful the issue with error 155 should be resolved.
Posted by Kevin Jaufmann-ludwig at 10:28 AM in Error Messages, HOT ISSUES!, Vault Professional\Manufacturing | Permalink
TrackBack
TrackBack URL for this entry:
http://www.typepad.com/services/trackback/6a01156eaaf373970c017ee6028824970dListed below are links to weblogs that reference Error 155 Illegal Null Parameter during Assign Item in Vault Pro 2013:
Comments
Verify your Comment
Previewing your Comment
Posted by: |
This is only a preview. Your comment has not yet been posted.
Your comment could not be posted. Error type:Your comment has been posted. Post another commentThe letters and numbers you entered did not match the image. Please try again.
As a final step before posting your comment, enter the letters and numbers you see in the image below. This prevents automated programs from posting comments.
Having trouble reading this image? View an alternate.
Involves backup and repair/reinstall, which could take a while, but will remove the error.

No comments:
Post a Comment